City of Largo, Florida

City of Largo, Florida
Department Image
Technical Specifications

Technical Specifications


booth


Stage Specifications

Proscenium opening 35'
Stage right wing space 17'
Stage left wing space 14'

Curtain line to upstage wall 34'
Curtain line to downstage edge 11'

Orchestra pit cover depth 6'
Curtain line to cyclorama 26'

Crossover space / cyclorama to upstage wall 8'


Sound

The Largo Cultural Center's Tonne playhouse has a professional full range stereo sound system consisting of two overhead clusters flown on the left and right side of the stage.
Sub bass cabinets are located at floor level.

Full range speakers are Renkus-Heinz TC-3 speaker clusters
Sub bass cabinets are (2) JBL loaded Double 18" encloseres 2KW capacity
The full range clusters are powered by (4) Crest CA9 amplifiers
The Subwoofers are powered by (4) Renkus-Heinz P3500 amplifiers
The house mixer is a Yamaha M7CL-48 with 48 microphone inputs, 8 DCA, 16 auxiliary sends and 8 Matrix.
House equalization is done with a DBX 2031
DBX drive rack house processor/crossover
40 ch Split snake w/ ISO and 8 return
24 ch stage box w/ 50 XLR
*All cable by CBI
The control room is located approximately 80' from the front curtain line. Full control of sound and lights are provided at this location

Outboard Equipment
(1) American Audio Dual CD w/ Cue Controller
(1) Sony MXD-D400 mini disc / compact disc player and recorder
(1) Sony RCD-W500C dual compact disc player and recorder
(1) Numark submixer w/ ipod input

Monitors
Stage monitors can be mixed from the control room or from the stage
The stage monitor desk is an Allen & Heath GL2000 24 x6
Six monitor mixes are possible with Rane GE60 Equalizers
Stage monitors are powered by:(6) Crown 24 x 6

Available monitor speakers are :
(6) EAW JFX 560 Floor Wedges (Bi-amp or Passive)


Microphones
(8) Shure Beta 58 Dynamic Microphone(1) Shure Beta 52 Dynamic Microphone
(1) Shure Beta 57 Dynamic Microphone
(8) Shure SM57 Dynamic Microphone
(1) Shure SM81 Condenser Microphone
(3) Shure SM99 Condenser Podium Microphone
(1) Sennheiser 421 Microphone
(3) Sennheiser Evolution Clip on Drum Microphone
(1) AKG D112 Dynamic Microphone
(2) Audio Technica AT859QMLX Unipoint Consenser Podium Microphone
(3) Audio Technica Pro 37R Condenser Microphone
(2) Crown CM31 Condenser Hanging Choir Microphone
(2) Crown PCC Condenser Microphone
(2) Whirlwind Hotbox Active DI
(2) Whirlwind EDB1 Passive DI
(2) Behringer Active DI
(3) Ramtech Pro DI

* Mic stands by K&M / Ultimate



Wireless Systems
(10) Shure UHF U14D/50 wireless microphone system (hand held or body pack)
(6) Handheld Beta 58 wireless handset
(10) Body pack transmitter with Sennheiser elements.
P { margin-bottom: 0.08in; }A:link { color: rgb(0, 0, 128); text-decoration: underline; }

Road Power
1-400 amp per leg 3-phase service located off stage right in Scene Shop

Lighting
The Largo Cultural Center's Tonne Playhouse is equipped with 96 Strand 2.4kw dimmers.
Six (6) circuits are dedicated to house lighting; 90 are available for theatrical lighting.
All lighting instruments are manufactured by Altman or ETC
The lighting console in the control room is a microprocessor-based Flying Pig Hog III with Dual 15" touch screens, Programming Wing and 30 playbacks.
Follow spots:2 Altman Satellite

Rigging
Locking rail........................Stage left
Loading Bridge..................Grid height
Counterweight lines...........21 single purchase line sets holding 1500# each
Length of battens................40'
3 line sets dedicated to Electrics
1 line set is dedicated to the 18' x 24' front projection screen


Draperies
Legs.................................4-Sets black, 1-Set red
Borders............................4-Black,1-Red
Travelers..........................1-upstage,1-midstage
Scrim................................1
Cyclorama.........................2 Seamless sky blue

Intercom
The Largo Cultural Center has a two-channel Clear-Com system.
The outlets are located as follows:
Dressing room
Orchestra pit
Stage left, back and front
Stage right, back and front
Scene shop
Dimmer room
Ticket office
Spot bays, left and right
Vestibule, left and right
Control room






There are (9) 501 belt packs with headset and (1) RM220 base stations

Projection
18' x 24' front projection screen / 9' x 12' rear projection screen
(2) NEC NP 4100 DLP projector
(1) Kramer VP728 Video Switcher w/ 3 way splitter

*Video control is from the stage


Loading
The loading dock leads into a 23' x 39' scene shop which leads to upstage right.
The loading dock is elevated 3' from ground level and has a 10' wide x 12' high door.

Dressing Rooms
There are two dressing rooms
Women's 13' x 17'
Men's 13' x 14'
Each dressing room has a toilet, shower, 4 sinks and a clothing rack.
The Green room is 33' x 8'. It is equipped with mirrors, furniture and a telephone.

Other Amenities Available
Baldwin 6' Baby Grand Piano (on Stage)
Steinway Upright Grand Piano (orchestra pit)
Stage Risers: Four (4) 8' x 6' x 24" with skirting and 2 stair units
Lectern
Step Ladders
Genie Lift
Ramp

Backstage Regulations
The LCC's Technical Supervisor or House Technician will assist with all technical needs and requirements. The authority of the Technical Supervisor with regards to safety issues and The LCC's equipment will be absolute.

The Lessee and/or Performers shall provide the Technical Supervisor with a full and detailed outline of show requirements, not less than 15 days prior to the first occupancy of the premises, including all stage, lighting, sound and hall requirements (schematics) and such other information as may be appropriate to the event to be presented.

The Lessee and/or Performer shall provide, not less than 7 days prior to the first occupancy of the premises, with a written production schedule, outlining all details for your event.

Example:
8 am - 9 am Load in
9 am - 10 am Sound set up
10 am - 11 am Sound check
11 am - 12 pm Doors
12 pm - 2 pm Show
2 pm - 3 pm Load out

SAFETY PROVISIONS: The Lessee and/or Performer agrees that all drapes, hangings, curtains, drops, and other decorative materials used in the premises shall be flame-proof and that all matters involving safety be resolved by the decision of the Lessor.


CARE AND USE OF THE THEATER: The Lessee and/or Performer shall not use any type of tape, adhesives or drive any nails, screws, tacks, pins, and/or any other objects into the floors, walls, partitions, doors, seats, or woodwork of the premises without the authority of the Technical Supervisor.

THE USE OF CONFETTI, GLITTER OR OBJECTS THAT MEASURE LESS THAN 1/4" IN SIZE/DIAMETER IS STRICTLY PROHIBITED.



Contact

Joe Ingrao
Technical Supervisor
727-587-6740 X5119
jingrao@largo.com

Brett Branning-Theater Technician
bbranning@largo.com

Scott Dempster -Theater Technician
sdempster@largo.com

The Largo Cultural Center
105 Central Park DR
Largo, FL 33771-2112

Mailing Address:
P O Box 296
Largo, FL 33779-0296

Office: 727-587-6751
Fax: 727-587-6773



Largo Cultural Center Line set Schedule

Line set

Purpose

DS Edge Distance

Notes

0

Fire Curtain



0

Dead Hung Pipe



1

Border



2

Legs



3

House Curtain



4

PROJECTION SCREEN



5

1ST ELECTRIC



6




7




8




9

2ND ELECTRIC



10

BLACK DRAW



11




12




13




14




15

3RD ELECTRIC



16




17




18




19




20

CYCLORAMA



21

BLACK DRAW














Related Pages

Share |

Contact Us

105 Central Park Dr
Largo, FL 33771
Get Directions

In This Department

Department Home
Special Topics

More Information